CVE-2019-3929: Crestron Multiple Products Command Injection Vulnerability

RBRecent Breaches Vulnerability Intelligence·Apr 15, 2022
High⚠ Actively exploited (CISA KEV)
High
Severity
Active
CISA KEV
No
Ransomware use
May 6, 2022
Patch deadline
⚠ Exploited in the wild. CISA added CVE-2019-3929 to its Known Exploited Vulnerabilities catalog on Apr 15, 2022, with a federal patch deadline of May 6, 2022 — meaning attackers are actively using it. If you run the affected software, patch it immediately.

Multiple Crestron products are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system…

CVE-2019-3929 is a command-injection flaw affecting multiple Crestron products. An unauthenticated remote attacker can reach the file_transfer.cgi HTTP endpoint and run operating-system commands with root privileges. Because the products are commonly deployed in conference rooms, control systems, and networked AV environments, successful exploitation can give an attacker full control of the device and a foothold into the surrounding network.

IT and security teams should treat any internet-reachable or poorly segmented Crestron instance as high priority until the vendor updates have been confirmed applied.

How it works

The vulnerability is described as command injection through the file_transfer.cgi HTTP endpoint. Although the recorded CWE identifier is CWE-79, the practical weakness is that user-supplied input reaches a command interpreter without adequate sanitization. A remote attacker who can send HTTP requests to the endpoint can therefore inject shell metacharacters or additional commands. Because the service runs as root, any injected command executes with the highest privileges on the device. No authentication is required, so the attack surface is simply network reachability of the affected interface. Exact request format and payload construction must be confirmed against the vendor advisory; defenders should not rely on public proof-of-concept details that may be incomplete or outdated.

Am I affected? How to find it in your systems

Crestron hardware and software appear in enterprise meeting rooms, digital signage, building-control networks, and similar AV/IT convergence environments. Inventory every Crestron appliance, touch panel, controller, and management server that exposes an HTTP or HTTPS management interface. Check device model and firmware version against the list published in the vendor advisory for CVE-2019-3929; do not assume a product is safe simply because it is not named in secondary sources. Look for the presence of the file_transfer.cgi endpoint on listening web services. Review web-server access logs and any centralized syslog or SIEM feeds for unexpected POST or GET requests that target that CGI path, especially those containing shell metacharacters, encoded payloads, or anomalous parameter lengths. Network scans that identify Crestron HTTP banners or MAC OUI ranges can help locate forgotten devices on user or guest VLANs.

How to remediate

The primary action is to apply the updates supplied by Crestron exactly as directed in the vendor advisory. CISA’s required action is simply “Apply updates per vendor instructions.” After patching, verify the new firmware or software version is running and that the file_transfer.cgi endpoint no longer accepts unsanitized input. As general hardening for this class of device, disable any unused web services, enforce authentication on all management interfaces, place the devices on dedicated management VLANs with strict ACLs, and ensure outbound traffic from the devices is limited to only necessary destinations. Retain configuration backups before and after the update so that unexpected behavior can be rolled back cleanly.

If you can't patch immediately

Until the vendor update can be installed, reduce exposure by network segmentation: move affected Crestron devices behind firewalls or ACLs that permit management access only from a small set of jump hosts or administrative subnets. Block external and unnecessary internal access to the HTTP/HTTPS ports that serve file_transfer.cgi. If a web application firewall or reverse-proxy is already in the path, consider temporary virtual-patch rules that drop or sanitize requests containing obvious command-injection patterns, while recognizing that such rules are incomplete. Disable the file-transfer or related CGI functionality if the product documentation allows it without breaking critical operations. Increase monitoring: alert on any connection attempts to the endpoint, on process-creation events that originate from the web service account, and on unexpected outbound connections from the device. Document the compensating controls and set a firm deadline for permanent patching.

If your data may have been exposed

Actively exploited command-injection vulnerabilities frequently lead to device compromise and subsequent lateral movement or data theft. If logs or other evidence suggest the endpoint was reached by an untrusted party, treat the device as untrusted, isolate it, and perform a full forensic review. As a quick additional check, you can run a free exposure scan of your email addresses against known breach data sets to see whether credentials or personal information have already appeared in public leaks.

AICompiled with AI assistance from public sources and published under our editorial standards.