CVE-2013-0631: Adobe ColdFusion Information Disclosure Vulnerability

RBRecent Breaches Vulnerability Intelligence·Mar 7, 2022
High⚠ Actively exploited (CISA KEV)
High
Severity
Active
CISA KEV
No
Ransomware use
Sep 7, 2022
Patch deadline
⚠ Exploited in the wild. CISA added CVE-2013-0631 to its Known Exploited Vulnerabilities catalog on Mar 7, 2022, with a federal patch deadline of Sep 7, 2022 — meaning attackers are actively using it. If you run the affected software, patch it immediately.

Adobe Coldfusion contains an unspecified vulnerability, which could result in information disclosure from a compromised server.

CVE-2013-0631 is an information disclosure vulnerability in Adobe ColdFusion. According to available public detail, an unspecified flaw can allow an attacker to obtain sensitive information from a compromised server. For IT and security teams running ColdFusion, this matters because disclosed configuration data, credentials, or application internals can enable further compromise even when the initial issue is not a full remote code execution path.

Public detail on exact mechanics is limited. Confirm affected releases, fixed builds, and any configuration prerequisites directly against the vendor advisory before prioritizing work.

How it works

This issue is classified as CWE-200 (Exposure of Sensitive Information to an Unauthorized Actor). In products of this class, the application or its administrative interfaces may return data that should remain internal—such as paths, configuration values, error details, or other server-side material—to a party that should not receive it.

An attacker who can reach the vulnerable ColdFusion instance would abuse the unspecified condition to pull that information from the server. The CISA summary frames the outcome as information disclosure from a compromised server; it does not document ransomware use. Specifics of the trigger, required privileges, or exact data types exposed are not provided in the given record and must be taken from the vendor advisory rather than assumed.

Am I affected? How to find it in your systems

Adobe ColdFusion is commonly deployed as an application server for web applications, often behind a web server or reverse proxy, on Windows or Linux hosts in data centers or cloud environments. It may appear in development, staging, and production tiers.

Inventory steps:

Telemetry and log signs of exploitation are not detailed in the public summary. In general for information-disclosure issues, look for unusual requests to administrative or diagnostic endpoints, repeated probing that returns verbose errors or configuration-like content, and outbound or access patterns inconsistent with normal application use. Correlate web and application logs with any existing IDS/WAF alerts. Confirm indicator guidance in the vendor advisory if it provides any.

How to remediate

Patch first. Apply the updates Adobe published for this vulnerability, following the vendor instructions referenced in the CISA required action. Validate the installed build after patching and re-check the advisory to ensure all listed components or hotfixes are in place.

After patching, harden along lines typical for this product class:

If you can't patch immediately

Reduce exposure until the vendor update can be applied:

These controls do not replace the official update. Schedule patching as soon as operationally feasible and confirm completion against the vendor advisory.

If your data may have been exposed

Actively exploited vulnerabilities can lead to broader breaches when disclosed information is reused for lateral movement or credential abuse. If you suspect exposure, preserve logs, rotate any credentials that may have been present on the server, and follow your incident-response process. You can run a free exposure scan of your email addresses against known breach data to see whether associated accounts appear in public breach corpora and then prioritize password changes and monitoring accordingly.

AICompiled with AI assistance from public sources and published under our editorial standards.

Details

AffectedAdobe · ColdFusion
WeaknessCWE-200
Added to CISA KEVMar 7, 2022
Federal patch deadlineSep 7, 2022
Known ransomware useNot documented
Check if your data is exposed →

Official records: NVD · CISA KEV

← All actively-exploited vulnerabilities